| A range of high quality toroidal
transformers with one 230V AC. winding and tappings provided
as per requirement. All leads for both input and output are
double-insulated, enameled wire, with stripped & tinned
wire ends thereby reducing assembly time. |
 |
| |
There are no air
gaps in the core & no vibrating laminations. The simple
construction of the toroid results in saving of weight as compared
to the conventional laminated type transformers. |
| |
High conductivity
copper winding on insulated toroidal core, made of high grade
cold rolled grain oriented silicon steel ensures very low magnetizing
currents & results in saving of power consumption, making
this range particularly attractive for compact power source
and slimline equipment. A further benefit of this gapless core
is the reduced level of radiated electrical noise (hum field). |
| |
TOROPOWER range of toroidal
transformers are available
- With Voltages as per customers specifications
up to 600 volts max.
- Also in sheet steel Enclosed or Resincast
models.
- With shield Between Primary and Secondary
windings if required.
|
| |
 |
| |
- 230 V A.C. Input & 115 A.C. Output 50/60
Hz.
- Popular voltage tappings 220-240 V A.C. also
feasible.
- Negligible wave form & power factor distortion.
- Excellent short time overload capacity.
- Small size and low weight as compared to
traditional stacked lamination type transformers.
- Extremely low level of radiated magnetic
field.
- Very low induced noise (hum)
- Very low iron loss & magnetizing current
& good regulation.
- Double insulated leads.
- Supplied with mounting kit having a single
hole mounting arrangement.
- 100% electrical and flash tested.
- High quality manufacturing and testing.
|
| |
 |
| |
| Rated |
Regulation |
Temp. |
Dimension |
Weight |
| VA |
% |
Rise °C |
Diameter
(mm) |
Height (mm)
|
Kg. |
| 1000 |
7 |
70 |
160 |
40 |
4.5 |
| 500 |
6 |
60 |
115 |
70 |
3.4 |
| 160 |
6 |
60 |
110 |
60 |
2.1 |
|
| |
- Allow 5 mm. extra, where leads emerge &
for mounting kit. Dimensions/Data are subject to change without
prior notice.
|
| |
 |
| |
Each transformer
is supplied with a dished washer, protection pads and nut, bolt
and washer for single hole fixing. The pads are to be fitted
above and below the transformer winding and the dished washer
on top of the upper pad.
Under no circumstances should
both ends of the fixing bolt contact a metal chassis or frame
as this would create 'a shorted turn' causing irreparable damage.
THESE TRANSFORMERS DO NOT